Mastervolt 2023

mastervolt.us POWER CONVERSION 56 Mass Systemswitch 16 kW Masterswitch 5 kW Masterswitch 3 kW (120V) Masterswitch 10 kW Part # 55008205 55006010 55006000 55006015 General Specifications Nominal input voltage 230V (50/60Hz) 230V (50/60Hz) 120V (50/60 Hz) 230V (50/60Hz) Input voltage range 200-250V AC 200-250V AC 100-125V AC 200-250V AC Number of inputs 3 2 2 2 Number of outputs 4 1 1 1 Dimensions, HxWxD 13.4" x 10.3" x 5.7" 340 x 261 x 144 mm 7.9" x 4.3" x 4.5" 200 x 110 x 115 mm 7.9" x 4.3" x 4.5" 200 x 110 x 115 mm 7.9" x 4.3" x 4.5" 200 x 110 x 115 mm Weight 11 lb / 5 kg 2.6 lb / 1.2 kg 2.6 lb / 1.2 kg 2.9 lb / 1.3 kg Technical Specifications Connection for remote control yes no no no MasterBus compatible yes no no no LED indication on cabinet indication voltage sources present and ‘load on inverter’ mode no no no Nominal input current generator 63A 20A 25A 40A Nominal input current shore 40A 20A 25A 40A Nominal input current inverter 25A n.a. n.a. n.a. Earth leakage switch no n.a. n.a. n.a. Generator input switch continuous monitoring of voltage and frequency no no no Time delay generator input 0-10 sec (adjustable) 0-10 sec (adjustable) 0-10 sec (adjustable) 0-10 sec (adjustable) Nominal current shortbreak output 25A n.a. n.a. n.a. Nominal current power output 40A 20A 20A 40A Nominal current generator output 63A n.a. 25A n.a. Automatical circuit breakers no, system dependent no, system dependent no, system dependent no, system dependent Power consumption (AC all inputs) 33 W 7 W 7 W 7 W Power consumption (only inverter power) <1 W 0 W 0 W 0 W Temperature range (specified) -23°F to 140°F (-31°C to 60°C) -23°F to 140°F (-31°C to 60°C) Temperature range (allowed) -13°F to 158°F (-25°C to 70°C) (may not meet the specified tolerances) -13°F to 158°F (-25°C to 70°C) (may not meet the specified tolerances) Temperature range (storage/non operating) -76°F to 176°F (-60°C to 80°C) -76°F to 176°F (-60°C to 80°C) -76°F to 176°F (-60°C to 80°C) -76°F to 176°F (-60°C to 80°C) Relative humidity maximum 95%, non condensing maximum 95%, non condensing Transfer time switch on 12-22 ms / switch off 4-19 ms switch on 12-22 ms / switch off 4-19 ms Frequency watch yes no no no Cable size 0.5-10 mm2/AWG 20-7, remote control: 0.14-2.5 mm2/AWG 26-13 0.5-10 mm2/AWG 20-7 0.5-10 mm2/AWG 20-7 0.5-10 mm2/AWG 20-7 Protection degree IP23 IP55 IP55 IP55 For detailed specifications, scale drawings, 3D files, certificates, manuals and 120V models see mastervolt.us. Transfer Systems Specifications Advantages of the Mastervolt transfer system • Activating and selecting 230V sources: Grid power, inverter and generator (adjustable to amperage of grid power, for instance 6A) • Prevents parallel connection between inverter and other 230V sources, avoiding damage to the inverter • Fully compatible with Mastervolt systems, and suitable for installations from other brands, other generators and/or inverters 120V

RkJQdWJsaXNoZXIy MjgzMDI=