mastervolt.us TRANSFORMERS 98 Mass GI 3.5 Mass GI 7 IVET 3.5 IVET 4.5 Part # 88000355 88000705 85000350 85000450 Input Input voltage 90–255V 90–255V 110/220/240V (adjustable) 110/220/240V (adjustable) Input frequency 45–65Hz 45–65Hz 45–65Hz 45–65Hz Nominal input current at 230V 16A 32A 16A 20A No load consumption 22 W 44 W <10 W <10 W Earth leakage protection no no no no Output Output voltage (equal to input) 90–255V, ± 5% 90–255V, ± 5% 110/220/240V, ± 5% 110/220/240V, ± 5% Output frequency equal to input equal to input equal to input equal to input Soft Start yes yes option option Switch off behaviour breaker B-characteristic B-characteristic n.a. n.a. Efficiency >93% >93% >93% >93% General Specifications Power 3500 W (up to 4 units parallel = 14 kW) 7000 W 3500 W 4500 W Technology high frequency high frequency E-core E-core Dimensions, HxWxD 13.4" x 10.3" x 5.7" 340 x 261x 144 mm 13.4" x 10.3" x 9.8" 340 x 261 x 250 mm 13" x 7.9" x 7.3" 330 x 200 x 185 mm 13" x 9.4" x 7.3" 330 x 240 x 185 mm Weight 13.2 lb / 6 kg 22 lb / 10 kg 66.1 lb / 30 kg 77.2 lb / 53 kg Ambient temperature 32°F to 104°F, derating power > 104°F (0°C to 40°C, derating power > 40°C) Switch off at 176°F / 80°C 176°F / 80°C n.a. n.a. Cooling variofan variofan natural cooling natural cooling Operating humidity max. 95% max. 95% max. 95% max. 95% Protection degree IP23 IP23 IP00 IP00 MasterBus compatible yes yes no no Options EasyView 5 77010310 option option n.a. n.a. Waterproof system monitor with ‘daylight readable’ color display and intuitive multi-language touchscreen to show the key system information at a glance. There is also a logbook feature for warnings and alarms, along with a buzzer and alarm notifications. The home button gives access to favorite pages. Soft Start 13 kW 55003300 included included option option Automatic switch that suppresses the inrush current from the isolation transformer to prevent the shore power fuse from blowing. Soft Start 22 kW 55003400 included included n.a. n.a. Automatic switch that suppresses the inrush current from the isolation transformer to prevent the shore power fuse from blowing. Isolation Transformers Specifications For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us. 6 kVA 9 kVA 13 kVA Soft Start 13 kVA Soft Start 22 kVA Part # 55010600 55010900 55011300 55003300 55003400 Voltage 120/230V 120/230V 120/230V 230V 230V Power 6 kW 9 kW 13 kW 2.5–13 kW 13–22 kW Max. input current 60A at 120V 30A at 230V 80A at 120V 40A at 230V 130A at 120V 70A at 230V n.a. n.a. Dimensions, HxWxD 15.7" x 11.8" x 8.3" 400 x 300 x 210 mm 15.7" x 11.8" x 8.3" 400 x 300 x 210 mm 15.7" x 11.8" x 8.3" 400 x 300 x 210 mm 7.9" x 7.1" x 4.5" 200 x 180 x 115 mm 7.9" x 7.1" x 4.5" 200 x 180 x 115 mm Weight 26.5 lb / 12 kg 27.6 lb / 12.5 kg 28.7 lb / 13 kg 2.6 lb / 1.2 kg 3.3 lb / 1.5 kg Transfer systems with Soft Start and automatic detection of the input voltage

RkJQdWJsaXNoZXIy MjgzMDI=