Mastervolt 2023

mastervolt.us POWER CONVERSION 28 AC Master Inverters Specifications – 12V * On/off control for the AC Master sine wave inverter with a clear on/off indicator which indicates when the inverter is active. In addition, the AC Master Remote Control makes it possible to turn the inverter on or off automatically by means of a 12-volt input, for example when switching on the onboard AC power or while starting an engine. The AC Master Remote Control comes with 25 ft (8 m) cable. 120V 120V AC Master 12/700 (120V) AC Master 12/2000 (120V) AC Master 12/300 AC Master 12/500 Part # 28510700 28512000 n.a. n.a. Part # (with UK plug) n.a. n.a. n.a. n.a. Part # (with NZ/AU plug) n.a. n.a. n.a. n.a. Part # (with IEC outlet) n.a. n.a. 28010302 28010502 General Specifications Output voltage 100/110/115/120 V — 50/60 Hz (selectable) 230V – 50 Hz (± 0.1%) 230V – 50 Hz (± 0.1%) Output waveform true sine true sine true sine true sine Nominal battery voltage 12V 12V 12V 12V Recommended battery capacity ≥ 100 Ah ≥ 200 Ah ≥ 60 Ah ≥ 100 Ah Continuous power at 77°F (25°C) , cos phi 1 700 W 2000 W 300 W 500 W Continuous power at 104°F (40°C), cos phi 1 700 W 2000 W 250 W 400 W Peak load < 810 W (1 min.) < 1230 W (1 sec.) < 2300 W (1 min.) < 3500 W (1 sec.) 600 W 800 W AC connection North American socket with GFCI North American socket with GFCI universal universal Efficiency 91 % 92% 90% 90% Parallel configuration n.a. n.a. n.a. n.a. 3-Phase configuration n.a. n.a. n.a. n.a. Display/read-out LED indication: battery voltage, load level, status LED display LED display Dimensions, hxwxd 7.9" x 13" x 3.3" 200 x 330 x 83 mm 9.8" x 17.4" x 3.3" 248 x 443 x 83 mm 8.3" x 5.1" x 2.4" 210 x 130 x 60 mm 8.3" x 5.1" x 2.4" 210 x 130 x 60 mm Weight 6 lb / 2.7 kg 11.5 lb / 5.2 kg 2.55 lb / 1.16 kg 2.69 lb / 1.22 kg Alarms potential free alarm contact potential free alarm contact 4 alarm modes 4 alarm modes Approvals safety: UL 458, EMC: FCC class B safety: UL 458, EMC: FCC class B CE, E-mark, ABYC A-31 CE, E-mark, ABYC A-31 Technical specifications Technology high frequency, input & output fully isolated high frequency, input & output fully isolated Input current (nominal load) 70A 200 A 22.5A 37.5A No-load power consumption (energy saving mode) < 0.1A < 0.1 A 0.33A – 4 W 0.33A – 4 W Minimal DC fuse (slow blow) 100A 250 A 2x 40A 2x 40A Minimal cable size 25 mm2 70 mm2 1.5 meter DC cable delivered as standard Harmonic distortion typical < 5% < 3 % < 6% < 6% Cos phi all power factors allowed all power factors allowed Transfer system n.a. n.a. n.a. n.a. Temperature range (ambient temp.) -4°F to 140°F, derating power > 104°F (-20°C to 60°C, derating power > 40°C) Protection degree IP21, horizontal wall mounting IP23, vertical wall mounting Protections over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) over-temperature, overload, short circuit, high/low battery voltage Cooling temperature and load controlled fan natural/forced natural/forced MasterBus compatible yes, using a MasterBus AC Master Interface Part # 77032700 no no Options AC Master Remote Control* 70405080 option option n.a. n.a. MasterBus AC Master Interface Integrates the AC Master inverter in a MasterBus network 77032700 option option n.a. n.a.

RkJQdWJsaXNoZXIy MjgzMDI=