mastervolt.us POWER CONVERSION 29 For detailed specifications, dimensional drawings, 3D files, images, certificates and manuals see mastervolt.us/inverters. AC Master 12/700 AC Master 12/1000 AC Master 12/1500 AC Master 12/2000 AC Master 12/2500 AC Master 12/3500 28010700 28011000 28011500 28012000 28012500 28013500 28210700 28211000 28211500 n.a. 28212500 28213500 28410700 28411000 28411500 n.a. 28412500 28413500 n.a. n.a. n.a. n.a. n.a. n.a. 200/220/230/240V — 50/60 Hz (selectable) 200/220/230/240V — 50/60 Hz (selectable) 230/240V — 50/60 Hz (selectable) true sine true sine true sine true sine true sine true sine 12V 12V 12V 12V 12V 12V ≥ 100 Ah ≥ 130 Ah ≥ 160 Ah ≥ 200 Ah ≥ 270 Ah ≥ 360 Ah 700 W 1000 W 1500 W 2000 W 2500 W 3500 W 700 W 1000 W 1500 W 2000 W 2500 W 3500 W < 810 W (1 min.) < 1230 W (1 sec.) < 1150 W (1 min.) < 1750 W (1 sec.) < 1730 W (1 min.) < 2650 W (1 sec.) < 2300 W (1 min.) < 4000 W (1 sec.) < 3000 W (1 min.) < 4000 W (1 sec.) < 4500 W (1 min.) < 6000 W (1 sec.) plug connection EU (Schuko) or UK plug connection EU (Schuko) or UK plug connection EU (Schuko) or UK plug connection EU (Schuko) hardwired + plug connection EU (Schuko) hardwired + plug connection EU (Schuko) 91% 92% 93% 94% 88% 90% n.a. n.a. n.a. n.a. yes, up to 15 units yes, up to 15 units n.a. n.a. n.a. n.a. yes, 3 units yes, 3 units LED indication: battery voltage, load level, status LED indication: battery voltage, load level, status LED indication: battery voltage, load level, status 7.9" x 13" x 3.3" 200 x 330 x 83 mm 7.9" x 14.6" x 3.3" 200 x 372 x 83 mm 9.8" x 16.6" x 3.3" 248 x 421 x 83 mm 9.8" x 17.4" x 3.3" 248 x 443 x 83 mm 11.1" x 17.2" x 5" 283 x 436 x 128 mm 11.1" x 19.5" x 5" 283 x 496 x 128 mm 6 lb / 2.7 kg 7.3 lb / 3.3 kg 9.3 lb / 4.2 kg 11.5 lb / 5.2 kg 17.6 lb / 8 kg 22 lb / 10 kg potential free alarm contact potential free alarm contact potential free alarm contact potential free alarm contact potential free alarm contact potential free alarm contact CE, E-mark, RCM CE, E-mark, RCM CE, E-mark, RCM CE, Safety: EN609501, E-mark: CISPR25, ISO11452-2, ISO7637-2, EMC: EN55022, EN55024, EN61000- 3-2; -3-3, EN61000-4,2,3,4,5,6,8,11 CE, E-mark, RCM CE, E-mark, RCM high frequency, input & output fully isolated high frequency, input & output fully isolated high frequency, input & output fully isolated 70A 100A 150A 200 A 250A 350A < 0.1A < 0.1A < 0.1A < 0.1 A < 1.1A < 1.4A 100A 125A 175A 250 A 300A 400A 25 mm2 35 mm2 50 mm2 70 mm2 95 mm2 120 mm2 < 5% < 5% < 3% < 5 % < 3% < 3% all power factors allowed all power factors allowed all power factors allowed n.a. n.a. n.a. n.a. integrated, automatic (inverter to grid: 8~10 ms, grid to inverter: 16~50 ms). Not for parallel & 3-phase operation (external transfer system possible). -4°F to 140°F, derating power > 104°F (-20°C to 60°C, derating power > 40°C) IP21, horizontal wall mounting IP21, horizontal wall mounting IP21, horizontal wall mounting over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) temperature and load controlled fan temperature and load controlled fan temperature and load controlled fan yes, using a MasterBus AC Master Interface Part # 77032700 yes, using a MasterBus AC Master Interface Part # 77032700 yes, using a MasterBus AC Master Interface Part # 77032700 option option option option option option option option option option option option

RkJQdWJsaXNoZXIy MjgzMDI=